23

OverviewTranscribeVersionsHelp

Here you can see all page revisions and compare the changes have been made in each revision. Left column shows the page title and transcription in the selected revision, right column shows what have been changed. Unchanged text is highlighted in white, deleted text is highlighted in red, and inserted text is highlighted in green color.

2 revisions
shiiyuri at Feb 04, 2019 08:27 AM

23

1155 5 May

Terminating resistors on MRS pulses to each
core box have been changed from 100Ω
to 47Ω in hope that it stops the
noise bug on these pulse lines
and put and end to the mystical core
hang up bug - let us see.

Randy

10:30 Ran dectape test as follows

Unit 3 UTEST, DCTEST, EXDATA

On one scratch tape use EXDATA found
some bad block marks but ran fine with
another scratch tape.
Ran ALLMODE on bad tape and then ran
EXDATA again. Its now good tape.
All in all the units tested seemed okay.

Randy

11:55 TS Main ran fine for 10 min.
Auto BLT for 13 min an it to is okay.

SNAFU

Randy

23