Seattle Wash Jan 16th 1890
Geo W. Hall Esq
Chr Police and Health Committee
City of Seattle
Sir
I propose to put in systems for heating
Water at the City Jail as follows. Furnish and set up a Galvanized
Iron Boiler Capacity 24 gallons set on substantial iron brackets
provided with a copper or brass pipe coil perforated with small
holes connected with steam direct to boiler also connected to
cold water with draw cock for hot water extended into
corridor all complete ready for use also furnish the following
Firing tools also tools to keep the apparatus in good order
1 Iron Poker
1 Do Clinker rake
1 Tube cleaner with handle
1 12" Monkey wrench
1 10 Gas plyers
All complete for the sum of forty-five ($45.00) Dollars
Respectfully submitted
John S. Christy