Pages
26
22
0115 14 Jan 68 Survey of the disk now shows: TEMP=90½° F Rose to 90° F at 1700 14 Jan 68. Stopped there until ~1930 and then gradually rose until it got to 90½° F by 2030. Steady since then.
Errors occur at recoverable unless otherwise noted.
Band8 | TK | SA8 |
---|---|---|
172 | 0 | 2271 |
202 | 0 | 154, 160, 170, 2124 |
2153, 2156, 2200 | ||
2207 etc | ||
215 | 0 | 33 |
Pass Complete | ||
172 | 0 | 2253 |
202 | 0 | 1, 11, 12, 2206, 2266, 2279 |
131 | 0 | 42, 126 |
213 | 0 | 111 |
Pass Complete | ||
172 | 0 | 42 |
202 | 0 | 6, 10, 17, 21, 40, 70 etc |
0210 14 Jan 68 Read error 205-2-53 SRR
27
[notebook page 23]
07:50 1/15/68 Found system had died at 12:43 this morning. System would not start using 16K DEC DUMP. Used Hand Waver to Re-initialize system. J. Gleason
[printout taped to page] CORE PARITY ERROR, LOCATION 000000051552 OPND = 000057777777 PC = 350000040152 INSTR = 602000400000 DATE=000641076157 TIME=0942:35 Core 2 [handwritten] 10:46 1/15/68 [Fred Parifund?] [end printout]
11:00 1/15/68 Line Printer is inserting spurious line feeds into listings. GLS
1155 15-Jan-68 Found disk saying "read error". Band=13310, TRK=2, SAR=238, INHIBIT READ COMPARE, UNIT REPEAT, TRK SET REPEAT, READ. FAST (OFF LINE) TEMP=90°. All relevant indicators are functioning. Recoverable. Turned off TRK, SET REPEAT. Read error, Band=13010, TRK=0, SAR=1608. Recoverable. Read error, Band = 8910, TRK=0, SAR=57. Recoverable. Read error, Band=13010, TRK=0, SAR=63. Recoverable.
28
Put system in Band Repeat with Band=13010
Read errors:
TRK // SAR // notes
0 // 2266 // recoverable 0 // 63 // " 0 // 16 // " 0 // 47 // " 0 // 63 // " 0 // 16 // " 0 // 57 // " 0 // 16 // " 0 // 63 // " 0 // 13 // " 0 // 2272 // " 0 // 102 // " 0 // 103 // " 0 // 57 // " 0 // 2256 // " 0 // 63 // " 0 // 146 // " 0 // 63 // " 0 // 6 // " 0 // 63 // two times 0 // 61 // recoverable 0 // 61 // " 0 // 167 // " 0 // 63 // " 0 // 34 // " 0 // 63 // " 0 // 107 // " 0 // 27 // " 0 // 107 // "
29
TRK // SAR // notes 0 // 63 // recoverable 0 // 57 // " 0 // 63 // " 0 // 57 // " 0 // 63 // " 0 // 54 // " 0 // 63 // " 0 // 34 // " 0 // 63 // " 0 // 63 // " 0 // 63 // " 0 // 16 // " 0 // 35 // " 0 // 63 // " 0 // 160 // " 0 // 21 // " 0 // 27 // " 0 // 57 // " 0 // 103 // " 0 // 54 // " 0 // 35 // "
In trying to switch to band 131 found that one of the indicators was out (low order bit of band register). This would not affect the above results. Lamp was replaced on the spot. The MTBF of the above errors was a few seconds. Band 131 seems much better. No errors in the ten minutes of run. I will put the system in read-
30
[notebook page] 26
only, all bands and tracks. John Sauter 1240 15-JAN-67
1400 15-Jan-68 Read error band 2018 tk 0 Recoverable Still read only testing SRR
1425 15 Jan 68 Read error 202-0-63 Recoverable Temp = 89° SRR
[add -20 low other light?]
1540 15 Jan 68 Found TTY 4 printing "B" sometimes when "C" key is pushed. Played a short while trying to find bug. Bug went away and now there are no errors. Magic! Ted Panofsky